Engines / Diesel / 2.0/75kW TDI-CR CUUx UDS EDC17C64 / Test - SCR heating: Circuit 2 - AD-Blue (Z103;Z104))
Mark
Model
Control unit
Diagnostic operation
Mark
Škoda
VW
Audi
Seat
Porsche
Bentley
MAN
Service intervals
Engines
Gearboxes
Immobilizers
auxiliary heater
Model
UDS Engines by part number
Diesel
Petrol
Control unit
1.4/55 kW 3V TDI PD AMF/BMS/BNM/BNV
1.6/55kW TDI-CR CAYA
1.6/55kW TDI-CR CAYE
1.6/66/77kW TDI-CR CLHx UDS
1.6/66kW TDI-CR CAYB
1.6/75kW TDI-CR CAYD
1.6/77kW TDI-CR CAYC;CLNA
1.9/47 kW SDI ASY
1.9/50kW SDI AGP;AQM EU-3
1.9/66 kW TDI AGR; ALH
1.9/66kW TDI-PD BRU; BXF
1.9/74 kW TDI etc
1.9/74kW TDI BEW;BRM
1.9/74kW TDI-PD AVQ
1.9/74kW TDI-PD BMT
1.9/75/62 kW TDI BRS;BRR
1.9/77 kW TDI PD
1.9/77kW TDI-PD AXB; AXC
1.9/77kW TDI-PD BKC; BJB; BXE
1.9/77kW TDI-PD BLS; BVB; BXJ; BSU
1.9/81kW TDI AHF;ASV EU 3
1.9/85kW TDI-PD BKE;BRB
1.9/96kW TDI
2.0/100 kW TDI-PD BGW
2.0/100/103kW TDI-PD BLB;BNA;BRE;BRF;BVF;BVG
2.0/100/103kW TDI-PD-DPF BRE
2.0/103kW TDI-CR CBAx
2.0/103kW TDI-CR CFFx;CFGx;CFHx;CLCx;CMGB UDS EDC17 C46
2.0/103kW TDI-PD BKD; AZV
2.0/103kW TDI-PD BMM;BMP
2.0/103kW TDI-PD BPW;BRC
2.0/103kW TDI-PPD BKP;BMA;BVE;BWV
2.0/103kW TDI-PPD BRT
2.0/120;125kW TDI-PPD BRD;BVA
2.0/125kW TDI-PD BMN; BMR; BUY; BUZ
2.0/75kW TDI-CR CUUx UDS EDC17C64
2.5/110kW TDI 6V AFB; AKE; AKN; AYM; BAU; BCZ; BDG; BDH; BFC
2.5/110kW TDI AFB; AKN
2.5/114 kW TDI 6V AYM
2.5/120kW TDI 6V BDG
2.5/128 kW TDI-PD BAC
2.5/128/120/96 kW TDI-PD AXE; BLJ AXD
2.5/128/96 kW TDI BPC; BNZ
2.7 TDI CR
3.0 TDI CR
3.0 V6 TDI BKS BMK BUN (3.0L V6TDI)
4.0 TDI CR
4.2 TDI CR
5.0/230 kW TDI-PD AYH
6.0 TDI CR
COMMON PROCEDURES
Continental SIMOS PCR 2.1 Continental CAYx UDS general
EDC 15 general
EDC 16 general
EDC 17 CAN general
EDC 17 UDS general
Diagnostic operation
Security access
Bleeding of fuel system
Zero detection of SRC additive level - AdBlue
Deletion of an error message SCR - AdBlue - dashboard
reset - Use the SRC system to block the starter - AdBlue
Check the leakproofness of the lines AdBlue - SCR
Emptying of the system AdBlue SCR
Reducing agent AD-Blue - status check
Error message identification AdBlue SCR dashboard
Test - Dosing of the reducing agent SCR AdBlue
zeroing learning values: additive injection system
basic settings - Zero detection of SRC additive level
Measurement of compression pressure
bleeding (deaeration) - Engine cooling
DPF regeneration - when vehicle is parked
zeroing learning values - Lambda sensor(s)
zeroing learning values - Adaptation of the mean quantity value
zeroing learning values - turbo blower
zeroing learning values - cylinders: pressure sensor
Deletion of statistics memory - Start-Stop
zeroing learning values - Intake air mass sensor
zeroing learning values - Low-pressure exhaust gas return valve
Start/Stop - activation/deactivation
adaptation: oil presure for engine run-in
customer limitation of maximum speed
basic settings - exhaust gas return valve 1 (GX5)
basic settings - turbo blower
basic settings - Low-pressure exhaust gas return valve
basic settings - adaptation - Test: throttle valve
basic settings - exhaust gas flap
basic settings - Neutral gear sensor (G701)
Test of gas pedal position sensor 1;2 (G79); (G185)
activation - fuel pump (G6)
Test - exhaust recirculation - servo engine (V338)
Test - exhaust recirculation CUUx
Test - exhaust gas return valve 1 (GX5)
Test of filling and atmospheric pressure sensor (G31)
Test of intake air temperature sensor (G42)
Test of engine temperature sensor (G62)
Test - Intake air mass sensor CUUx
Test of fuel temperature sensor (G81)
Test of exhaust gases temperature sensor 2;3;4 (G448; G495;G648) CUUx
Test - fuel pressure - pressure sensor (G247) CUUx
Test of DPF differential pressure sensor 1 (G505) CUUx
Test - temperature sensor: Reducing agent AD-Blue (G685)
Test - Level sensor: Reducing agent (G697)
Test - Evaluation unit: Reducing agent (G698)
Test - Neutral gear sensor (G701)
Test of heating (glow) unit (J179)
Test of radiator fan control unit (J293)
Test - voltage: terminal 30 (J317)
Test - throttle valve: control unit (J338)
Test - small heat capacity relay (J359)
Test - large heat capacity relay (J360)
Test - SCR heating - AD-Blue (J891)
Test - Starter control (J906)
Test - fuel pump: control unit (J538)
Test - injector 1-4 (N30;N31;N32;N33)
Test - filling pressure control valve (N75) CUUx variant 1
Test - filling pressure control valve (N75) CUUx variant 2
Test - fuel pressure regulation vlave (N276) CUUx
Test - return quantity from component: fuel pressure regulation vlave (N276)
Test - Fuel metering valve (N290) CUUx
Test - additive pump SCR AD-Blue (V437)
Test - SCR heating: Circuit 2 - AD-Blue (Z103;Z104))
Test - additive tank: SCR heating - AD-Blue (Z102)
Test - Intake air temperature sensor (G42)
Test - intercooler - temperature sensor (G811)
Test - ambient temperature sensor - temperature sensor (G17)
Test - coolant temperature - temperature sensor (G62)
Test - Lambda-sensor downstream of catalyst (G130)
Test - Lambda-sensor upstream of catalyst (G39)
Diagnostic procedure
You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR onl y You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and You will get login to diagnostic procedures database imediatelly.
Log-in
Buy
Note:
- on-board voltage > XXV
XX - Actuators
select item in drop-down menu:
IDEXXXXX - SCR excitation - heating of block X
In the Actuators window, click Measured values and select the items you want to visualize.
IDEXXXXX - heating of block X Dosing of the reducing agent: voltage
IDEXXXXX-ENGXXXXXX - heating of block X Dosing of the reducing agent: excitation Bits X-X
TIP! For easier search in the menu, enter the code IDE, ENG or MAS into the "Filter" window
XX - Actuators - Start
desired condition :
IDEXXXXX-ENGXXXXXX = XX, XX - the value must change according to the actual condition heating of block
IDEXXXXX = X - XX XX mV - the value must change according to the actual condition heating of block
back
XX - error memory
desired condition :
Error memory empty
End of test
You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR onl y You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and You will get login to diagnostic procedures database imediatelly.
Log-in
Buy