Engines / Petrol / 1.6/75kW BGU/BSE/BSF/CCSA/CMXA / Test - Lambda-sensor upstream of catalyst - voltage
Search:Search area:
Mark
Model
Control unit
Diagnostic operation
Displayed 1-20 records out of 100.
<< < 1 > >>
Mark
Model
Control unit
Diagnostic operation
Diagnostic procedure
You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR only You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and You will get login to diagnostic procedures database imediatelly.
Conditions: - exhaust system - tightness of line - OK - engine temperature > XX °C
- catalyst temperature > XXX °C (XX - Measured values group XXX field X) - second mechanic necessary!
- observe the occupation safety rules when taking a test drive with connected diagnostics tester
Start the engine
wait XXX s
do a test drive - engine speed XXXX rpm - XXXX rpm
XX - Measured values group XXX
required values field X:
xxxxX = lambda control = active
xxxXx = lambda control = readiness for operation
xx?xx = heating of lambda probe(s)
upon achievement of values - engine speed = idling
XX - Measured values group XXX required values
field X = -XX% - +XX% - fluctuates (lambda control value)
field X = X,XV - X,XV - fluctuates (voltage of lambda probe(s))
if values are not achieved - field X < -XX% - rich mixture - check component:
- injector - tightness of line
- fuel pressure - high
- spark-plugs
- electromagnetic valve for the active carbon box - open
- heating of lambda probe(s)
- Lambda sensor(s)
if values are not achieved field X > +XX% - poor mixture - check component: - exhaust system - tightness of line - fuel pressure - low - injector - clogged - heating of lambda probe(s) - Lambda sensor(s)
if values are not achieved field X = X - emergency mode -check component:
- exhaust system - tightness of line
- engine speed - idling
- injector - clogged, tightness of line
- spark-plugs
- electromagnetic valve for the active carbon box - open
- heating of lambda probe(s)
- Lambda sensor(s)
if values are not achieved field X - check component:
- Lambda sensor(s) line - short-circuit to GND ???
- Lambda sensor(s) - replace
You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR only You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and You will get login to diagnostic procedures database imediatelly.