You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR only You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and You will get login to diagnostic procedures database imediatelly.
Conditions:
- engine temperature >= XX °C (XX - Measured values group XXX field X)
- catalyst temperature > XXX °C (XX - Measured values group XXX field X)
- parking brake = ON
- gear engaged (P) (automatic transmission)
- on-board voltage > XX V (XX - Measured values group XXX field X)
Note:
- The readiness Code must be created as the last diagnostics task. Later deletion of the memory could also result in deletion of the created readiness Code.
connect with the control unit XX - engine
Start the engine - engine speed = idling
delete error memory
switch-off the engine
switch on the ignition
connect with the control unit XX - engine
XX - Basic settings group XXX
activate default settings
wait XX s (follow the diagnostics instructions)
required values
field X = ADP-OK (may take several minutes)
upon achievement of values - continue
XX - Basic settings group XXX
activate default settings
wait XX s (follow the diagnostics instructions)
required values
field X = ADP-OK (may take several minutes)
upon achievement of values - continue
Start the engine - engine speed = idling
XX - Basic settings group XXX
activate default settings
wait XX s (follow the diagnostics instructions)
required values
field X = Syst-OK (may take several minutes)
upon achievement of values - continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = ADP-OK (may take several minutes)
upon achievement of values
release - brake pedal + accelerator pedal
continue
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = xXxXxxxx (may take several minutes)
upon achievement of values
release - brake pedal + accelerator pedal
continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
required values
field X = Syst-OK (may take several minutes)
upon achievement of values
continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
required values
field X = Syst-OK (may take several minutes)
upon achievement of values
continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = BX-SX OK (may take several minutes)
upon achievement of values - release - brake pedal + accelerator pedal
continue
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = BX-SX OK (may take several minutes)
upon achievement of values - release - brake pedal + accelerator pedal
continue
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = ADP-OK (may take several minutes)
upon achievement of values - release - brake pedal + accelerator pedal
continue
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = CAT-BX OK (may take several minutes)
upon achievement of values - release - brake pedal + accelerator pedal
continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
required values
field X = EVAP OK (may take several minutes)
upon achievement of values
continue
XX - Measured values group XXX
required values
field X = XXX (Lambda-sensor upstream of catalyst)
field X = XXx (Lambda-sensor downstream of catalyst)
Significance of code:
Xxx = heating of lambda probe(s)
xXx = readiness for operation
xxX = lambda control
if values are not achieved - increase rpm to XXXX rpm
wait XX MIN
required values
field X = XXX (Lambda-sensor upstream of catalyst)
field X = XXx (Lambda-sensor downstream of catalyst)
upon achievement of values
engine speed = XXXX rpm
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = TEST ON
wait
required values
field X = Syst-OK
upon achievement of values - release - brake pedal + accelerator pedal
continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
sharply depress - accelerator pedal
required values
field X = XXX
upon achievement of values - continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = Syst-OK
upon achievement of values - release - brake pedal + accelerator pedal
continue
XX - Basic settings group XXX
activate default settings
from XXXX rpm, accelerate in Xrd gear to about XXXX rpm
required values
field X = Syst-OK (may take several minutes)
upon achievement of values - continue
engine speed = idling
wait X minutes
check download of the readiness code of the readiness functions
if values are not achieved:
check of error memory
do a test drive
- idling
- partial load
- full load (engine speed > XXXX rpm)
- deceleration
repeate this test
- engine temperature >= XX °C (XX - Measured values group XXX field X)
- catalyst temperature > XXX °C (XX - Measured values group XXX field X)
- parking brake = ON
- gear engaged (P) (automatic transmission)
- on-board voltage > XX V (XX - Measured values group XXX field X)
Note:
- The readiness Code must be created as the last diagnostics task. Later deletion of the memory could also result in deletion of the created readiness Code.
connect with the control unit XX - engine
Start the engine - engine speed = idling
delete error memory
switch-off the engine
switch on the ignition
connect with the control unit XX - engine
XX - Basic settings group XXX
activate default settings
wait XX s (follow the diagnostics instructions)
required values
field X = ADP-OK (may take several minutes)
upon achievement of values - continue
XX - Basic settings group XXX
activate default settings
wait XX s (follow the diagnostics instructions)
required values
field X = ADP-OK (may take several minutes)
upon achievement of values - continue
Start the engine - engine speed = idling
XX - Basic settings group XXX
activate default settings
wait XX s (follow the diagnostics instructions)
required values
field X = Syst-OK (may take several minutes)
upon achievement of values - continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = ADP-OK (may take several minutes)
upon achievement of values
release - brake pedal + accelerator pedal
continue
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = xXxXxxxx (may take several minutes)
upon achievement of values
release - brake pedal + accelerator pedal
continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
required values
field X = Syst-OK (may take several minutes)
upon achievement of values
continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
required values
field X = Syst-OK (may take several minutes)
upon achievement of values
continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = BX-SX OK (may take several minutes)
upon achievement of values - release - brake pedal + accelerator pedal
continue
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = BX-SX OK (may take several minutes)
upon achievement of values - release - brake pedal + accelerator pedal
continue
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = ADP-OK (may take several minutes)
upon achievement of values - release - brake pedal + accelerator pedal
continue
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = CAT-BX OK (may take several minutes)
upon achievement of values - release - brake pedal + accelerator pedal
continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
required values
field X = EVAP OK (may take several minutes)
upon achievement of values
continue
XX - Measured values group XXX
required values
field X = XXX (Lambda-sensor upstream of catalyst)
field X = XXx (Lambda-sensor downstream of catalyst)
Significance of code:
Xxx = heating of lambda probe(s)
xXx = readiness for operation
xxX = lambda control
if values are not achieved - increase rpm to XXXX rpm
wait XX MIN
required values
field X = XXX (Lambda-sensor upstream of catalyst)
field X = XXx (Lambda-sensor downstream of catalyst)
upon achievement of values
engine speed = XXXX rpm
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = TEST ON
wait
required values
field X = Syst-OK
upon achievement of values - release - brake pedal + accelerator pedal
continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
sharply depress - accelerator pedal
required values
field X = XXX
upon achievement of values - continue
engine speed = idling
XX - Basic settings group XXX
activate default settings
fully depress - brake pedal + accelerator pedal
required values
field X = Syst-OK
upon achievement of values - release - brake pedal + accelerator pedal
continue
XX - Basic settings group XXX
activate default settings
from XXXX rpm, accelerate in Xrd gear to about XXXX rpm
required values
field X = Syst-OK (may take several minutes)
upon achievement of values - continue
engine speed = idling
wait X minutes
check download of the readiness code of the readiness functions
if values are not achieved:
check of error memory
do a test drive
- idling
- partial load
- full load (engine speed > XXXX rpm)
- deceleration
repeate this test
You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR only You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and You will get login to diagnostic procedures database imediatelly.