Conditions:
- exhaust system - tightness of line = OK
- appliances = OFF
- engine speed = idling
- engine temperature > XX °C
- catalyst temperature > XXX °C
connect with the control unit XX - engine
XX - Measured values group XXX
required values
field X = XXx (Lambda-sensor downstream of catalyst - status)
?xx = heating of lambda probe(s)
x?x = readiness for operation
xx? = lambda control
if values are not achieved - increase rpm to XXXX - XXXX rpm
wait
required values
field X = XXx (Lambda-sensor downstream of catalyst - status)
upon achievement of values - increase rpm to XXXX - XXXX rpm
XX - Basic settings group XXX
activate default settings
depress and hold - brake pedal + accelerator pedal
required values
field X = -X.X - X.X V - fluctuates (voltage of lambda probe(s))
field X = XXXXXXX
if values are not achieved - field X - check component:
- field X =< - X,X V - Lambda sensor(s) - interruption or short-circuit to GND
- field X >= X,X V - Lambda sensor(s) - interruption or short-circuit to +XXV
upon achievement of values - continue
release - brake pedal + accelerator pedal
XX - Measured values group XXX
required values
field X = XXX °C - XXX °C (catalyst temperature)
field X = X,X V - X,X V (signal NOx)
field X = X,X V - X,X V
- exhaust system - tightness of line = OK
- appliances = OFF
- engine speed = idling
- engine temperature > XX °C
- catalyst temperature > XXX °C
connect with the control unit XX - engine
XX - Measured values group XXX
required values
field X = XXx (Lambda-sensor downstream of catalyst - status)
?xx = heating of lambda probe(s)
x?x = readiness for operation
xx? = lambda control
if values are not achieved - increase rpm to XXXX - XXXX rpm
wait
required values
field X = XXx (Lambda-sensor downstream of catalyst - status)
upon achievement of values - increase rpm to XXXX - XXXX rpm
XX - Basic settings group XXX
activate default settings
depress and hold - brake pedal + accelerator pedal
required values
field X = -X.X - X.X V - fluctuates (voltage of lambda probe(s))
field X = XXXXXXX
if values are not achieved - field X - check component:
- field X =< - X,X V - Lambda sensor(s) - interruption or short-circuit to GND
- field X >= X,X V - Lambda sensor(s) - interruption or short-circuit to +XXV
upon achievement of values - continue
release - brake pedal + accelerator pedal
XX - Measured values group XXX
required values
field X = XXX °C - XXX °C (catalyst temperature)
field X = X,X V - X,X V (signal NOx)
field X = X,X V - X,X V