Engines / UDS Engines by part number / 01 - Engine [EV_ECM12TFS02103F906070FP 004005] / Zeroing learning values DPF - If replaced: pressure difference sensor (G505)
Mark
Model
Control unit
Diagnostic operation
Mark
Škoda
VW
Audi
Seat
Porsche
Bentley
MAN
Service intervals
Engines
Gearboxes
Immobilizers
auxiliary heater
Model
UDS Engines by part number
Diesel
Petrol
Part 1 of the order number
03C
03E
03F
03H
03L
03N
03P
04B
04C
04E
04L
05C
05E
05L
06J
06K
07C
07P
0EA
1K8
2G0
2H6
36A
3G0
3W0
4G0
4G1
4G2
4G5
4H0
4K0
4KE
4L0
4L1
4L2
4M0
4M8
4ML
4N0
4S0
5FA
5G0
5H0
5N0
5NA
5WA
760
7P0
7P1
7P5
80A
81A
83A
8K0
8K1
8K2
8K5
8R0
8S0
8T0
8T1
8T2
8U0
8V0
8W0
8Y0
W03
W04
W4G
Control unit
Diagnostic operation
Start/stop - activation/deactivation
Customer limitation of maximum speed
Zeroing learning values DPF - If replaced: pressure difference sensor (G505)
Deletion of statistics memory - Start-stop
Automatic test procedure
Creation of readiness
Basic settings - adaptation - Test: throttle valve
Activation - fuel pump (G6)
Test of filling and atmospheric pressure sensor (G31)
Test of intake air temperature sensor (G42)
Test of engine temperature sensor (G62)
Test of radiator fan control unit (J293)
Test - low heat performance relay (J359)
Test - high heat performance relay (J360)
Test - fuel pump: control unit (J538)
Test - injector 1-4 (N30;N31;N32;N33)
Test - filling pressure control valve (N75) - variant 2
Kick-down - adaptation
Test - pump of cooling liquid - Change-over valve (N492)
Test - Charge Pressure Controller - Position sensor (G581)
Test - Charge Pressure Controller - Position sensor II (G581)
Test - throttle actuator
Test - additional cooling pump - relay
Test - engine control unit (J623) - power supply
Test - fuel pressure - pressure sensor (G247)
Test - Fuel metering valve (N290) CBZB
Test - filling pressure control valve (N75)
Test / activation of fuel pump and control relay
Test of filling and atmospheric pressure sensor (G31 G71 J623)
Test of gas pedal position sensor 1 - voltage (G79)
Test of gas pedal position sensor 1; 2 (G79; G185)
Test of gas pedal position sensor 2 - voltage (G185)
Test of engine temperature sensor - outlet from radiator (G83)
Test of fuel temperature sensor (G81)
Test of pedal switches (cruise control)
Test of cruise control
Erasing of learning values
Bleeding of fuel system
Charge Pressure Controller - adaptation
Evacuation of fuel tank
Zeroing learning values - Adaptation of the mean quantity value
Creation of readiness
Customer limitation of maximum speed
Default throttle valve settings
Zeroing learning values
Deletion of statistics memory Start-stop
Bleeding of fuel system
Bleeding of fuel system variant II
Evacuation of fuel tank
Evacuation of fuel tank II
Creation of readiness
Automatic test procedure
Test - electromagnetic valve for the active carbon box (N80) variant 2
Test of gas pedal position sensor 1; 2 (G79; G185)
Test of intake air temperature sensor (G299)
Erasing of learning values
Test: fuel pressure regulation vlave (N276)
Test: temperature sensor - ambient temperature (G17)
Test: lambda control
Settings - Charge Pressure Controller - NOsetelný servo motor (V465)
Snížení Pressureu v railu
Kick-down - adaptation
Test - filling pressure control valve (N75)
Test of filling and atmospheric pressure sensor
Zeroing learning values - Adaptation of the mean quantity value
Creation of readiness
Basic settings - exhaust gas flap
Test - filling pressure control valve (N75) CUUx variant 1
Diagnostic procedure
You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR onl y You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and You will get login to diagnostic procedures database imediatelly.
Log-in
Buy
Note:
- done after replacement of component : pressure difference sensor (GXXX)
Conditions:
- engine speed = X rpm
- Error memory empty
- on-board voltage > XX.X V
connect with the control unit XX - engine
XX - Security access
enter value: XXXXX
Start
XX - Basic settings
select item in drop-down menu: IDEXXXXX - zeroing learning values: pressure difference sensor
activate default settings
follow the diagnostics instructions
required values: Successfully completed
if values are not achieved -> check of error memory
XX - end of communication
End of test
You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR onl y You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and You will get login to diagnostic procedures database imediatelly.
Log-in
Buy