Engines / UDS Engines by part number / 56 - Radio [EV_ECM16TDI02103L906023AG 003011] / Test of exhaust gases temperature sensor 1; 3 (G235; G495; 648)
Mark | Model | Control unit | Diagnostic operation |
---|
Mark

Model

Part 1 of the order number 

Control unit 

Diagnostic operation 

Diagnostic procedure
You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR only You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and You will get login to diagnostic procedures database imediatelly.
Conditions:
- engine temperature = XX°C +
connect with the control unit XX - engine
Start the engine
engine speed = idling
wait XXs
Advanced Measured Values
select item in menu:
IDEXXXXX-ENGXXXXXX - temperature of exhaust gases X-TEG_MES[X] (temperature upstream of component: turbo blower)
IDEXXXXX-ENGXXXXXX - temperature of exhaust gases X-TEG_MES[X] (temperature upstream of component: Diesel Particulate Filter)
IDEXXXXX-ENGXXXXXX - temperature of exhaust gases X-TEG_MES[X] (temperature downstream of component: Diesel Particulate Filter)
TIP! For easier search in the menu, enter the code IDE, ENG or MAS into the "Filter" window
increase rpm to XXXX rpm
desired condition:
X-TEG = increasing - strongly
X-TEG, X-TEG = increasing - moderately
X-TEG > X-TEG > X-TEG
for this test, it is suitable to use graphical representation VagScope
example:
if values are not achieved - check component:
- temperature sensor
- wiring
- connector connections
- engine temperature = XX°C +
connect with the control unit XX - engine
Start the engine
engine speed = idling
wait XXs
Advanced Measured Values
select item in menu:
IDEXXXXX-ENGXXXXXX - temperature of exhaust gases X-TEG_MES[X] (temperature upstream of component: turbo blower)
IDEXXXXX-ENGXXXXXX - temperature of exhaust gases X-TEG_MES[X] (temperature upstream of component: Diesel Particulate Filter)
IDEXXXXX-ENGXXXXXX - temperature of exhaust gases X-TEG_MES[X] (temperature downstream of component: Diesel Particulate Filter)
TIP! For easier search in the menu, enter the code IDE, ENG or MAS into the "Filter" window
increase rpm to XXXX rpm
desired condition:
X-TEG = increasing - strongly
X-TEG, X-TEG = increasing - moderately
example:
if values are not achieved - check component:
- temperature sensor
- wiring
- connector connections
You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR only You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and You will get login to diagnostic procedures database imediatelly.