Seat / Leon (5F) / 08 - Air-conditioning AC Manuel [EV_ACManueBHBVW37X 003017] / Compressor run-in (air condition compressor - replacement)


Mark Model Control unit Diagnostic operation
Displayed 1-20 records out of 100. << < 1 > >>
Mark
Model
Control unit
Diagnostic operation
Diagnostic procedure

This operation was considered useful 1x.

You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR only You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and  You will get login to diagnostic procedures database imediatelly.

Volkswagen workshop manuals for diagnostics

Log-in Buy

Conditions:
- learning the end stops of the flaps (basic settings) -
Successfully completed
- load management - inactive
- error memory - faultless
- air-conditioning vents - open
- engine speed: idling
- do not switch-off the ignition and do not break the communication
- ventilation: ON

Note:
done after replacement of component
: air condition compressor


connect with the control unit XX - air-conditioning


XX - Adaptation

select item in drop-down menu: IDEXXXXX - Duration of compressor run-in

(For easier search in the menu, enter the code IDE, ENG or MAS into the "Filter" window )

enter value:
XX s

Start


select item in drop-down menu: IDEXXXXX - Duration of the compressor run-in basic settings

(
For easier search in the menu, enter the code IDE, ENG or MAS into the "Filter" window )

enter value:
XXX s

Start


XX - Actuators

select item in drop-down menu: IDEXXXXX - Adoption of exterior unfiltered temperature

Start

wait XX s


XX - Measured values

select item: IDEXXXXX - ambient temperature

select item: IDEXXXXX - ambient temperature - calculated value

(
For easier search in the menu, enter the code IDE, ENG or MAS into the "Filter" window )

desired condition:
ambient temperature = ambient temperature - calculated value


XX - Basic settings

select item in drop-down menu: IDEXXXXX - Compressor run-in

activate default settings

wait:
XXX s

End basic set-up


XX - Adaptation

select item in drop-down menu: IDEXXXXX - Duration of the compressor run-in basic settings

(For easier search in the menu, enter the code IDE, ENG or MAS into the "Filter" window )

enter value:
XX s

Start


check of error memory


desired condition: faultless


XX - end of communication


You are not logged! System works in DEMO mode only now where numbers are replaced with X characters. For 49 EUR only You will get access into full system. You can pay by credit card or bank transfer. Click BUY button for purchase and  You will get login to diagnostic procedures database imediatelly.

Volkswagen workshop manuals for diagnostics

Log-in Buy